Abstract

Displaced acromion fractures are commonly treated surgically; however, no implants have been specifically designed for this fracture type. Although various plates have been used, fixation failure and implant-related irritation remain concerns. We report a case of acromion fracture fixation using a proximal clavicle plate. A 77-year-old man presented with right shoulder pain after a fall. Computed tomography revealed an Ogawa type III acromion fracture extending to the spinoglenoid notch. Through a posterior approach along the scapular spine, the fracture was anatomically reduced and fixed with a proximal clavicle locking plate. Four screws, including two longer than 30 mm, were inserted medially to the fracture site, and six screws were inserted laterally. Neither fixation failure nor implant-related pain occurred, and complete bone union was achieved. Fixation with a proximal clavicle plate may represent a useful treatment option for acromion fractures, particularly in cases with highly variable acromial and scapular spine anatomy.

Introduction

Traumatic acromion fractures are rare, accounting for <1% of all fractures [1]. Displaced acromion fractures are associated with a high risk of symptomatic nonunion [2]; therefore, surgery is often indicated. Surgical procedures for acromion fractures include tension band wiring, hollow screw fixation, and plate fixation; however, owing to its rarity, there is no established gold-standard surgical procedure. Although plate fixation is considered to provide more rigid fixation than tension band wiring and screw fixation [3], no plates are specifically designed for acromion fractures and various types of plates have been used [2–11]. However, implant failure [2, 7, 8] and plate irritation [2, 3, 10, 11] can occur postoperatively.

We report a case of acromion fracture fixation using a proximal clavicle plate. To our knowledge, this is the first report describing the use of a proximal clavicle plate for fixation of an acromion fracture.

Case report

A 77-year-old man presented to our hospital with persistent right shoulder pain since a fall while climbing a mountain 3 days earlier. He had no significant medical history. He had difficulty moving his shoulder because of severe pain. Radiography showed displaced fractures of the acromion and coracoid process (Fig. 1). Computed tomography (CT) revealed an Ogawa type III acromion fracture [12] with a fracture line extending to the spinoglenoid notch (Fig. 2A) and an Ogawa type I coracoid process fracture [13] (Fig. 2B). Surgery was indicated because of disruption of the superior shoulder suspensory complex.

Preoperative anteroposterior and scapula-Y view of radiographs of the right scapula showing displaced acromion and coracoid process fractures.
Figure 1

Preoperative radiographs of the right scapula showing displaced acromion and coracoid process fractures.

Three-dimensional computed tomography (3D-CT) scans of the right scapula, consisting of two panels: (A) a fracture line of the acromion extending into the spinoglenoid notch (Ogawa classification type III), and (B) a fracture of the coracoid process (Ogawa classification type I).
Figure 2

CT of the right scapula. 3D-CT demonstrates an Ogawa type III acromion fracture with a fracture line extending to the spinoglenoid notch (A) and an Ogawa type I coracoid process fracture (B).

Surgery was performed with the patient in the left lateral recumbent position. For the acromion fracture, we made a skin incision along the scapular spine, exposing the fracture site (Fig. 3A). We reduced the fractured fragments and temporarily stabilized them with a Kirschner wire (Fig. 3B). After detaching 2 cm of the trapezius muscle attached to the acromion angle subperiosteally, we placed a proximal clavicle plate (VA-LCP® Clavicle Plate, Synthes, Oberdorf, Switzerland) on the dorsal border of the scapular spine. Because of the good anatomical fit of the plate to the scapular spine, only minor plate bending was required. We inserted one cortical screw and three locking screws medial to the fracture site, with the screw trajectories directed perpendicular to the scapular spine. Two of the four screws had lengths >30 mm. One cortical screw and five locking screws were inserted lateral to the fracture site (Fig. 3C). For the coracoid process fracture, we used a 4.0 mm-cannulated cancellous screw (MDM, Tokyo, Japan) for reduction and fixation (Fig. 4).

Intraoperative photographs of right acromion osteosynthesis in three steps: (A) exposing the displaced fracture via skin incision, (B) temporary fixation of reduced fragments with a Kirschner wire, and (C) definitive plate fixation along the scapular spine after partial trapezius muscle detachment indicated by a dashed line.
Figure 3

Intraoperative findings during osteosynthesis of the right acromion fracture. Using a skin incision along the scapular spine, a displaced acromion fracture is identified (A). Fracture fragments are reduced, and a Kirschner wire is placed to temporarily fix the fragments (B). After detaching 2 cm of the trapezius muscle attached to the acromion angle subperiosteally (dashed line), a proximal clavicle plate is placed on the dorsal border of the scapular spine (C).

Postoperative radiographs of the right scapula, demonstrating successful reduction and fixation of the scapula fracture and coracoid fracture using a plate and a cannulated cancellous screw, respectively.
Figure 4

Postoperative radiographs of the right scapula obtained immediately after surgery.

The affected arm was placed in a sling for 3 weeks. From 1 week postoperatively, active shoulder range-of-motion exercises and rotator cuff strength exercises within ˂90° of shoulder elevation were commenced. Full shoulder range-of-motion exercises were initiated 5 weeks postoperatively. Scapular stabilization exercises were initiated 9 weeks postoperatively.

Radiography performed 1 year postoperatively confirmed bone union without displacement of the fracture fragment (Fig. 5). The patient had no plate-related pain, and the range of shoulder motion (right/left) was 130/140° for anterior elevation and 30/40° for external rotation. The Constant score was 89 at 1 year postoperatively.

Postoperative radiograph images taken one year after surgery, confirming bone union of the right scapula and right coracoid fracture.
Figure 5

Postoperative radiographs of the right scapula obtained 1 year after surgery.

Discussion

In the present case, osteosynthesis using a proximal clavicle plate achieved solid bone union and satisfactory shoulder function without postoperative complications.

Plate fixation using straight plates [2–4, 6–8, 11], distal clavicle plates [3, 9–11], distal humerus plates [5, 8], and olecranon plates [8] has been reported for acromion fractures; however, the application of plates for proximal clavicle fractures has not been reported. Fixation using other plates has provided relatively good surgical outcomes [2, 4–9]. However, because of substantial anatomical variation in the scapular spine [14], implant failure [2, 7, 8] and plate irritation [2, 4, 14, 15] resulting from implant-anatomy mismatch have been reported [10]. In this case, these complications were not observed, and the postoperative functional score was comparable to that reported in previous studies [5, 6], suggesting that a proximal clavicle plate represent a useful alternative when conventional implants do not adequately match the highly variable anatomy of the acromion and scapular spine.

The proximal clavicle plate offered two additional advantages beyond its favorable anatomical fit. First, the placement of the proximal clavicle plate on the scapular spine enabled the insertion of sufficiently long screws that reached the anterior cortex of the scapular body. A previous biomechanical study showed that placing the locking plate on the dorsal subcutaneous border of the scapular spine reliably allowed longer screws, resulting in a strong fixed-angle construct medially, compared with plate placement on the supraspinatus fossa [15]. Another case series suggested that a medially extended plate and optimized screw fixation are important for preventing implant-related complications [11]. In this case, four screws (two >30 mm) were inserted medially to the fracture site, which may have contributed to the rigid fixation. Second, the proximal clavicle plate enabled the lateral insertion of a sufficient number of locking screws while minimizing the disruption of the deltoid and trapezius origin from the acromion angle. The lateral acromion is characterized by reduced thickness and a thin cortical shell; therefore, lateral fixation of the acromion is challenging [8]. The insertion of a sufficient number of locking screws in the lateral acromion presumably improves fixation strength [9, 10]. However, achieving such lateral fixation often requires extensive dissection of the deltoid and trapezius insertions at the acromial angle, particularly when distal clavicle plates are used. In this case, we were able to insert six screws lateral to the fracture site, maintaining a trapezius detachment at 2 cm, suggesting that the muscle dissection from the acromion angle was relatively minimal.

This case report highlights the potential utility of a proximal clavicle plate for fixation of acromion fractures. Osteosynthesis with a proximal clavicular plate can achieve anatomical reduction and rigid fixation of acromion fractures, with satisfactory postoperative outcomes. Proximal clavicle plate fixation may be a useful option for acromion fractures, particularly in patients with highly variable acromial and scapular spine anatomy.

However, the proximal clavicle plate is not indicated for Ogawa type I acromion fractures because plate placement along the anterior aspect of the acromion is difficult. Moreover, this report is limited by its single-case design and the absence of biomechanical comparison with other fixation methods. Further studies are needed to evaluate the reproducibility and broader applicability of this technique.

Author contributions

Y.Y. and R.F. conceptualized, collected, and interpreted the clinical data, and wrote the manuscript. A.T. and N.M. interpreted the clinical data, advised on the treatment of this case, and critically revised the manuscript for important content. All the authors have read and approved the final manuscript.

Conflicts of interest

None declared.

Funding

The authors certify that they or their institutions did not receive any support (e.g. grants, funding, payment, or other benefits) or a commitment or agreement to provide such benefits in connection with the research or preparation of this manuscript, except as disclosed in a separate attachment.

Data availability

Data supporting the findings of this study are available from the corresponding author upon request.

Ethics approval and consent to participate

This case report was approved by the Independent Ethics Committee of the Ashikaga Red Cross Hospital (Approval No. 2024–5). Consent to participate was not required for this study.

Consent for publication

Written informed consent was obtained from the patient for the publication of this case report and any accompanying images.

References

1.

Court-Brown
 
CM
,
Caesar
 
B
.
Epidemiology of adult fractures: a review
.
Injury
 
2006
;
37
:
691
7
.

2.

Anavian
 
J
,
Wijdicks
 
CA
,
Schroder
 
LK
 et al.  
Surgery for scapula process fractures: good outcome in 26 patients
.
Acta Orthop
 
2009
;
80
:
344
50
.

3.

Hill
 
BW
,
Anavian
 
J
,
Jacobson
 
AR
 et al.  
Surgical management of isolated acromion fractures: technical tricks and clinical experience
.
J Orthop Trauma
 
2014
;
28
:
e107
13
.

4.

Gorczyca
 
JT
,
Davis
 
RT
,
Hartford
 
JM
 et al.  
Open reduction internal fixation after displacement of a previously nondisplaced acromial fracture in a multiply injured patient: case report and review of literature
.
J Orthop Trauma
 
2001
;
15
:
369
73
.

5.

Hackl
 
M
,
Moro
 
F
,
Durchholz
 
H
.
Combined displaced fracture of the lesser humeral tuberosity and the scapular spine: a case report
.
Int J Surg Case Rep
 
2015
;
13
:
106
11
.

6.

Ogawa
 
K
,
Inokuchi
 
W
,
Matsumura
 
N
.
Delayed surgery for displaced fracture of the anatomic neck and spine of the scapula: a case report and literature review
.
JSES Open Access
 
2018
;
2
:
169
73
.

7.

Nunes
 
SR
,
Fernandes Filho
 
MR
,
Fernandes
 
MR
.
Acromion fracture and lateral angle of the scapular spine: case report and literature review
.
Int J Surg Case Rep
 
2019
;
60
:
353
7
.

8.

Toft
 
F
,
Moro
 
F
.
Does ORIF of rare scapular spine fractures sustained after reverse shoulder arthroplasty benefit elderly patients? A case-series appraisal
.
Orthop Traumatol Surg Res
 
2019
;
105
:
1521
8
.

9.

Cho
 
CH
,
Jung
 
JW
,
Lim
 
YJ
 et al.  
Acute displaced fracture of lateral acromion after reverse shoulder arthroplasty: a case report and surgical technique
.
Clin Shoulder Elb
 
2019
;
22
:
106
9
.

10.

Stoots
 
SJM
,
Derksen
 
RJ
.
The floating acromion: a rare and previously unreported injury possibly requiring surgical stabilization
.
Case Rep Orthop
 
2020
;
2020
:9465370.

11.

Bauer
 
S
,
Traverso
 
A
,
Walch
 
G
.
Locked 90-double plating of scapular spine fracture after reverse shoulder arthroplasty with union and good outcome despite plate adjacent acromion fracture
.
BMJ Case Rep
 
2020
;
13
:
e234727
.

12.

Ogawa
 
K
,
Matsumura
 
N
,
Yoshida
 
A
 et al.  
Nonunion of the so-called acromion: a systematic review with consideration of the terminology
.
Arch Orthop Trauma Surg
 
2023
;
143
:
5727
40
.

13.

Ogawa
 
K
,
Yoshida
 
A
,
Takahashi
 
M
 et al.  
Fractures of the coracoid process
.
J Bone Joint Surg Br
 
1997
;
79
:
17
9
.

14.

Lin
 
Y
,
Gan
 
K
,
Zhang
 
L
 et al.  
The anatomical variation of the scapular spine in a Chinese population
.
Med Sci Monit
 
2019
;
25
:
8863
72
.

15.

Ting
 
FSH
,
Lockhart
 
JS
,
Axford
 
D
 et al.  
Comparing internal fixation constructs for scapular spine insufficiency fractures following reverse shoulder arthroplasty
.
J Shoulder Elbow Surg
 
2021
;
30
:
172
7
.

This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.