PDF
- Split View
-
Views
-
Cite
Cite
Nader Abraham, Davide Schilliro, Spencer D Nichols, Benjamin Hughes, Andrew S Barbas, Neo-ureter reconstruction using tubularized bladder urothelium to salvage a shortened ureter in a non-human primate kidney transplant model, Journal of Surgical Case Reports, Volume 2026, Issue 11, November 2026, rjag1058, https://doi.org/10.1093/jscr/rjag1058
Close - Share Icon Share
Abstract
Ureteral complications are the most common urological adverse events after renal transplantation, and ischemia of the distal graft ureter is the usual cause of urine leak. Salvage is especially difficult in non-human primate (NHP) transplant models, where the recipient bladder is small and the graft ureter short. We report an NHP that developed a urine leak from a graft-to-native uretero-ureterostomy after renal transplantation. At re-exploration the distal graft ureter was necrotic; debridement left a length deficit precluding tension-free primary repair. We raised a mucosa-predominant bladder flap, tubularized it over a stent into a urothelial-lined neo-ureter in continuity with the bladder, and anastomosed it to the shortened graft ureter, without detrusor reinforcement, nor a psoas hitch. The reconstruction was patent and watertight with preserved graft function, rescuing a high-value preclinical experiment and offering a salvage option for transplant ureteral complications.
Introduction
Renal transplantation is the optimal treatment for end-stage kidney disease, and the non-human primate (NHP) is the highest fidelity large-animal model for studies of tolerance, xenotransplantation, and graft preservation. Urological complications are the most frequent technical adverse events after kidney transplantation, with an overall incidence of ~3%–11% and urine leak in ~1%–9% [1, 2]. Most leaks arise at the ureteral anastomosis and reflect ischemia of the distal graft ureter, whose blood supply depends entirely on collaterals from the renal hilar vessels [3]. When a leak results from frank distal necrosis, debridement to viable tissue creates a length deficit that constrains reconstruction. Classical options—ureteroneocystostomy with a psoas hitch, a full-thickness Boari flap, uretero-ureterostomy to the native ureter, ileal interposition, or auto-transplantation [3, 4]—are demanding in the NHP, where the recipient bladder is small and the graft ureter short and fragile. The bladder is an attractive substitute: it is urothelial-lined, distensible and well-vascularized, and bladder-derived grafts have an established experimental lineage [5–8]. We describe a salvage combining a mucosa-predominant tubularized bladder neo-ureter with a spatulated uretero-ureterostomy in an NHP.
Case report
A Rhesus Macaque NHP weighing ~5-kg underwent heterotopic renal allo-transplantation under an IACUC-approved protocol. The graft was re-vascularized to the recipient infra-renal aorta and inferior vena cava, and urinary continuity was restored by a spatulated uretero-ureterostomy between the graft and native ureter over a 3.7-Fr stent. Immediate graft function was observed. On postoperative Day 6 the animal developed reduced urine output, rising BUN and creatinine and abdominal distension. Urgent surgical abdominal exploration was performed, and a urine leak was confirmed by an ascitic creatinine markedly exceeding the serum value. The urinoma was evacuated. The distal graft ureter at the anastomosis was necrotic and dehisced, whereas the proximal ureter and renal pelvis were viable. The ureter was debrided to briskly bleeding tissue, leaving a shortened graft ureter with a deficit that precluded tension-free primary repair. The bladder was mobilized and distended with saline. Rather than a full-thickness Boari flap, a broad-based flap of bladder mucosa (urothelium with a thin layer of lamina propria), with its base-oriented postero-laterally to preserve perfusion and a length-to-width ratio kept at or below [2–3]:1. The flap was tubularized, urothelium inward, over a 4.7-Fr ×12 cm stent with running 6–0 Maxon suture, creating a urothelial-lined neo-ureter in continuity with the bladder. The shortened graft ureter and the neo-ureter were each spatulated and joined by a tension-free, uretero-ureterostomy over the indwelling stent (Fig. 1). No detrusor approximation, nor psoas hitch were performed. Watertight suture line was confirmed via foley distention of the bladder and neo-ureter with sterile normal saline. Recovery was uneventful. Serum creatinine normalized to 1 mg/dL. At the planned terminal timepoint, ~1-month later, the neo-ureter was grossly intact, patent, with a healed anastomosis and no urine leak or obstruction.

Neo-ureter reconstruction with tubularized bladder urothelium.
Discussion
This case illustrates a simple surgical salvage technique for the most consequential urological failure mode in transplant models—an ischemic distal graft-ureteral leak—using autologous bladder mucosal tissue to bridge the debridement deficit without the need for a psoas hitch or detrusor backing. Three features distinguish it. First, the construct is a mucosa-predominant tubularized neo-ureter rather than a full-thickness Boari flap. Limiting the harvest largely to urothelium reduces bulk and the volume of detrusor sacrificed. Experimental canine work shows that bladder tissue, including thickness-tapered and non-vascularized free grafts, can survive, remain patent, and retain a urothelial lining when used to reconstruct the ureter [6–8]. Second, the kidney is reconnected not by direct reimplantation but by a spatulated uretero-ureterostomy to the shortened graft ureter. This preserves the pelvis-to-ureter axis, places the high-risk anastomosis between two well-vascularized urothelial surfaces, and uses spatulation to widen the lumen and limit stricture, the principal late complication of bladder-flap repairs [4]. Continuity of the neo-ureter with the bladder provides distal drainage. The mucosa is distensible and elastic obviating the need for a psoas hitch, nor detrusor backing to offload tension. Third, demonstration in an NHP is more translationally relevant than the rodent and canine systems in which bladder substitutes are usually studied. NHP transplant experiments are resource-intensive and ethically weighty; a reliable urinary salvage protects both scientific yield and animal welfare, consistent with the principles of reduction and refinement. This is increasingly pertinent as extended-criteria and machine-perfused grafts, in which distal ureteral ischemia may be more likely, enter preclinical and clinical use. The report is limited to a single animal with limited follow-up; durability, the significance of any reflux through a non-tunneled anastomosis, and long-term graft outcome cannot be inferred. Prospective evaluation with standardized imaging and histology is warranted before the technique is adopted as a standard salvage.
Conflicts of interest
No conflicts of interest to declare.
Funding
None declared.