-
PDF
- Split View
-
Views
-
Cite
Cite
Ondrej Blecha, Ana C Belzarena, Jan Lesensky, Successful limb salvage and favorable functional outcome after subtotal scapulectomy and custom 3D-printed reconstruction in a 14-year-old with high-grade osteosarcoma, Journal of Surgical Case Reports, Volume 2026, Issue 11, November 2026, rjag1030, https://doi.org/10.1093/jscr/rjag1030
Close - Share Icon Share
Abstract
Scapular reconstruction following tumor resection remains a surgical challenge because of the scapula’s essential role in upper extremity biomechanics. Although patient-specific implants have expanded reconstructive options, achieving durable fixation and functional restoration remains difficult. A 14-year-old male with high-grade osteosarcoma of the scapular wing underwent limb-salvage surgery using a custom 3D-printed endoprosthesis. Preoperative planning incorporated dedicated software and patient-specific cutting guides. Wide resection preserved a small portion of the glenoid and the native glenohumeral joint to maximize postoperative function. At 3 months, radiographs demonstrated early osseointegration. The patient achieved 100° of active shoulder abduction without scapular winging or instability. At 2 years, he maintained near-full motion, demonstrated stable implant integration without loosening or recurrence, and returned to sports and daily activities with minimal limitations. Patient-specific scapular endoprosthetic reconstruction can achieve excellent oncologic and functional outcomes after subtotal scapulectomy, even in very young patients with high-grade malignancy.
Introduction
Primary scapular tumors are uncommon, and reconstruction after oncologic resection remains challenging because loss of the scapula can substantially compromise shoulder stability, motion, and strength [1–4]. When oncologically feasible, preservation of the native glenohumeral joint and key periscapular structures may improve function [3–5]. We report a pediatric high-grade osteosarcoma treated with subtotal scapulectomy and a patient-specific 3D-printed reconstruction designed to preserve the native joint.
Case report
Patient history
A 14-year-old male presented with a one-week history of pain and a palpable mass over the right scapula. Imaging demonstrated a large cystic lesion involving the scapular body (Figs 1–2). Fluid–fluid levels on magnetic resonance imaging (MRI) initially raised the possibility of an aneurysmal bone cyst. Open biopsy confirmed high-grade telangiectatic osteosarcoma. The patient underwent standard neoadjuvant chemotherapy followed by planning for definitive resection.

Initial radiographs with Y-view of the scapula (A) and anteroposterior view of the shoulder (B) demonstrating the scapular tumor.

MRI of the shoulder, axial (A) and sagittal (B) views showing the tumor in more detail, expanding the scapula. Fluid–fluid levels were present, which raised the differential diagnosis of an aneurysmal bone cyst.
Reconstruction plan
Following multidisciplinary consultation and shared decision-making with the patient and his parents, reconstruction with a patient-specific 3D-printed titanium endoprosthesis was selected. High-resolution computed tomography (CT) and MRI of both scapulae were fused to create a three-dimensional model (Figs 3–4), and a mirrored model of the contralateral scapula served as the reconstructive template. Patient-specific cutting guides were developed to permit a subchondral osteotomy adjacent to the glenoid while preserving the native glenohumeral joint. The plan also preserved the base of the coracoid, acromion, supraspinous region, supraspinatus muscle, and suprascapular nerve. Reconstruction of the scapular body and wing was intended to restore the shoulder-girdle contour and provide sites for anatomic muscle reattachment.

CT scan of the scapula with detailed 3D reconstruction for surgical planning.

MRI image with axial views of right scapula mirrored (A) for surgical planning and left scapula (B).
Implant
The implant was manufactured by laser sintering of Ti6Al4V titanium alloy with a diamond-like carbon surface coating [6, 7]. A 2-mm trabecular titanium scaffold was incorporated at bone–implant interfaces to promote osseointegration, while the scapular body used a lightweight lattice configuration (Fig. 5). A threaded interface at the glenoid portion permitted future fixation of a glenosphere should the native glenohumeral joint fail. Patient-specific instruments were manufactured to reproduce the planned osteotomy and implant position (Fig. 6). A full-scale prototype underwent feasibility assessment before final approval by the surgical and engineering teams.

Custom 3D-printed implant designed to reconstruct the resected portion of the scapula. The main body of the implant was designed as a lightweight lattice, reproducing the anatomic contour of the scapula.

Patient-specific instruments fabricated to facilitate accurate intraoperative resection and precise implant positioning.
Surgical procedure
The procedure was performed under general anesthesia with the patient prone using a modified Judet approach. A curvilinear incision extended from the acromion along the scapular spine to the inferior angle, and the biopsy tract was excised en bloc with the specimen. The trapezius and rhomboids were detached and retracted medially; the scapular spine was exposed, and the deltoid was detached. Inferior to the scapular spine, the infraspinatus and teres minor were transected to expose the posterior capsule. The teres major and serratus anterior were then transected, mobilizing the scapula from the thoracic wall. A patient-specific cutting guide was secured to uninvolved bone with Kirschner wires, and the planned osteotomy was performed. The subscapularis was transected along the osteotomy plane and the tumor-bearing scapula removed en bloc.
The custom implant was trialed and definitively fixed with two screws into the acromion, two into the residual supraspinous fossa, and one into the coracoid. A superior compression plate was added in a clamp-like configuration to secure the preserved scapular spine to the prosthesis. Implant position closely reproduced the preoperative plan. The remaining musculature was reapproximated over the implant, with the deltoid and trapezius reattached to the scapular spine through dedicated prosthetic fixation points. Complete soft-tissue coverage and stable thoracoscapular fixation were obtained without intraoperative instability. The wound was closed in layers, and the arm was immobilized in a supportive sling in neutral rotation for six weeks. Adjuvant chemotherapy was resumed. Physical therapy began at six weeks with progressive range of motion and loading; all restrictions were lifted at 3 months.
Outcomes
Final pathology demonstrated 100% tumor necrosis and negative margins. At 3 months, there was no scapular winging or anterior displacement, and the glenohumeral joint remained stable. The patient achieved full active external rotation, 100° of abduction, 70° of internal rotation, and normal elbow strength. Radiographs showed stable implant position without migration or loosening (Fig. 7). At 24 months, he had an MSTS score of 30/30, full active range of motion (Fig. 8), no evidence of recurrence, and unrestricted activities of daily living.

Follow-up radiograph of the patient demonstrating a well-seated and stable implant.

Clinical pictures of the patient demonstrating excellent functional outcome, with substantial restoration of active range of motion and no significant functional limitations.
Discussion
Scapular reconstruction aims to avoid the functional limitations of a flail shoulder after scapulectomy. Endoprosthetic reconstruction has shown better function than humeral suspension in selected patients [4], and contemporary series support custom-made or segmental 3D-printed scapular prostheses [8–10]. In this case, the principal reconstructive priority was not simply replacing the resected scapular body, but preserving the native glenohumeral joint and the small residual segment containing the glenoid, acromion, and coracoid. Preservation of these structures has been associated with superior postoperative function [3, 10, 11]. When the glenohumeral joint itself requires prosthetic reconstruction, constrained designs may provide stability but introduce risks including loosening and soft-tissue complications, without a clear functional advantage over unconstrained reconstruction [12, 13]. Double-constrained constructs may be useful when critical stabilizers must be sacrificed, but were unnecessary here because the native joint and key neuromuscular structures could be retained [14, 15].
Conclusion
This case highlights the unique reconstructive challenges posed by malignant scapular tumors in very young patients, in whom both oncologic control and long-term functional preservation are critical. The use of advanced preoperative planning, including patient-specific cutting guides and a custom 3D-printed endoprosthesis, enabled precise tumor resection with negative margins while preserving a portion of the native glenoid and the glenohumeral joint. This joint-preserving strategy proved to be a key determinant of the excellent functional outcome observed. The favorable oncologic and functional results in this case underscore the potential of patient-specific, technology-driven reconstruction to expand limb-salvage options in complex scapular tumors, particularly in the pediatric population, where durable function is of paramount importance.
Funding
None declared.
Conflicts of interest
None declared.
Institution(s) at which the work was performed: First Medical Faculty, Charles University, University Hospital Na Bulovce, Prague, Czech Republic.