Journal Article

Successful limb salvage and favorable functional outcome after subtotal scapulectomy and custom 3D-printed reconstruction in a 14-year-old with high-grade osteosarcoma

Journal of Surgical Case Reports, Volume 2026, Issue 11, November 2026, rjag1030, https://doi.org/10.1093/jscr/rjag1030
Published:
10 November 2026
Article history
Received:
09 August 2026
Accepted:
20 October 2026
Published:
10 November 2026

Abstract

Scapular reconstruction following tumor resection remains a surgical challenge because of the scapula’s essential role in upper extremity biomechanics. Although patient-specific implants have expanded reconstructive options, achieving durable fixation and functional restoration remains difficult. A 14-year-old male with high-grade osteosarcoma of the scapular wing underwent limb-salvage surgery using a custom 3D-printed endoprosthesis. Preoperative planning incorporated dedicated software and patient-specific cutting guides. Wide resection preserved a small portion of the glenoid and the native glenohumeral joint to maximize postoperative function. At 3 months, radiographs demonstrated early osseointegration. The patient achieved 100° of active shoulder abduction without scapular winging or instability. At 2 years, he maintained near-full motion, demonstrated stable implant integration without loosening or recurrence, and returned to sports and daily activities with minimal limitations. Patient-specific scapular endoprosthetic reconstruction can achieve excellent oncologic and functional outcomes after subtotal scapulectomy, even in very young patients with high-grade malignancy.

Introduction

Primary scapular tumors are uncommon, and reconstruction after oncologic resection remains challenging because loss of the scapula can substantially compromise shoulder stability, motion, and strength [1–4]. When oncologically feasible, preservation of the native glenohumeral joint and key periscapular structures may improve function [3–5]. We report a pediatric high-grade osteosarcoma treated with subtotal scapulectomy and a patient-specific 3D-printed reconstruction designed to preserve the native joint.

Case report

Patient history

A 14-year-old male presented with a one-week history of pain and a palpable mass over the right scapula. Imaging demonstrated a large cystic lesion involving the scapular body (Figs 1–2). Fluid–fluid levels on magnetic resonance imaging (MRI) initially raised the possibility of an aneurysmal bone cyst. Open biopsy confirmed high-grade telangiectatic osteosarcoma. The patient underwent standard neoadjuvant chemotherapy followed by planning for definitive resection.

For image description, please refer to the figure legend and surrounding text.
Figure 1

Initial radiographs with Y-view of the scapula (A) and anteroposterior view of the shoulder (B) demonstrating the scapular tumor.

For image description, please refer to the figure legend and surrounding text.
Figure 2

MRI of the shoulder, axial (A) and sagittal (B) views showing the tumor in more detail, expanding the scapula. Fluid–fluid levels were present, which raised the differential diagnosis of an aneurysmal bone cyst.

Reconstruction plan

Following multidisciplinary consultation and shared decision-making with the patient and his parents, reconstruction with a patient-specific 3D-printed titanium endoprosthesis was selected. High-resolution computed tomography (CT) and MRI of both scapulae were fused to create a three-dimensional model (Figs 3–4), and a mirrored model of the contralateral scapula served as the reconstructive template. Patient-specific cutting guides were developed to permit a subchondral osteotomy adjacent to the glenoid while preserving the native glenohumeral joint. The plan also preserved the base of the coracoid, acromion, supraspinous region, supraspinatus muscle, and suprascapular nerve. Reconstruction of the scapular body and wing was intended to restore the shoulder-girdle contour and provide sites for anatomic muscle reattachment.

For image description, please refer to the figure legend and surrounding text.
Figure 3

CT scan of the scapula with detailed 3D reconstruction for surgical planning.

For image description, please refer to the figure legend and surrounding text.
Figure 4

MRI image with axial views of right scapula mirrored (A) for surgical planning and left scapula (B).

Implant

The implant was manufactured by laser sintering of Ti6Al4V titanium alloy with a diamond-like carbon surface coating [6, 7]. A 2-mm trabecular titanium scaffold was incorporated at bone–implant interfaces to promote osseointegration, while the scapular body used a lightweight lattice configuration (Fig. 5). A threaded interface at the glenoid portion permitted future fixation of a glenosphere should the native glenohumeral joint fail. Patient-specific instruments were manufactured to reproduce the planned osteotomy and implant position (Fig. 6). A full-scale prototype underwent feasibility assessment before final approval by the surgical and engineering teams.

For image description, please refer to the figure legend and surrounding text.
Figure 5

Custom 3D-printed implant designed to reconstruct the resected portion of the scapula. The main body of the implant was designed as a lightweight lattice, reproducing the anatomic contour of the scapula.

For image description, please refer to the figure legend and surrounding text.
Figure 6

Patient-specific instruments fabricated to facilitate accurate intraoperative resection and precise implant positioning.

Surgical procedure

The procedure was performed under general anesthesia with the patient prone using a modified Judet approach. A curvilinear incision extended from the acromion along the scapular spine to the inferior angle, and the biopsy tract was excised en bloc with the specimen. The trapezius and rhomboids were detached and retracted medially; the scapular spine was exposed, and the deltoid was detached. Inferior to the scapular spine, the infraspinatus and teres minor were transected to expose the posterior capsule. The teres major and serratus anterior were then transected, mobilizing the scapula from the thoracic wall. A patient-specific cutting guide was secured to uninvolved bone with Kirschner wires, and the planned osteotomy was performed. The subscapularis was transected along the osteotomy plane and the tumor-bearing scapula removed en bloc.

The custom implant was trialed and definitively fixed with two screws into the acromion, two into the residual supraspinous fossa, and one into the coracoid. A superior compression plate was added in a clamp-like configuration to secure the preserved scapular spine to the prosthesis. Implant position closely reproduced the preoperative plan. The remaining musculature was reapproximated over the implant, with the deltoid and trapezius reattached to the scapular spine through dedicated prosthetic fixation points. Complete soft-tissue coverage and stable thoracoscapular fixation were obtained without intraoperative instability. The wound was closed in layers, and the arm was immobilized in a supportive sling in neutral rotation for six weeks. Adjuvant chemotherapy was resumed. Physical therapy began at six weeks with progressive range of motion and loading; all restrictions were lifted at 3 months.

Outcomes

Final pathology demonstrated 100% tumor necrosis and negative margins. At 3 months, there was no scapular winging or anterior displacement, and the glenohumeral joint remained stable. The patient achieved full active external rotation, 100° of abduction, 70° of internal rotation, and normal elbow strength. Radiographs showed stable implant position without migration or loosening (Fig. 7). At 24 months, he had an MSTS score of 30/30, full active range of motion (Fig. 8), no evidence of recurrence, and unrestricted activities of daily living.

For image description, please refer to the figure legend and surrounding text.
Figure 7

Follow-up radiograph of the patient demonstrating a well-seated and stable implant.

For image description, please refer to the figure legend and surrounding text.
Figure 8

Clinical pictures of the patient demonstrating excellent functional outcome, with substantial restoration of active range of motion and no significant functional limitations.

Discussion

Scapular reconstruction aims to avoid the functional limitations of a flail shoulder after scapulectomy. Endoprosthetic reconstruction has shown better function than humeral suspension in selected patients [4], and contemporary series support custom-made or segmental 3D-printed scapular prostheses [8–10]. In this case, the principal reconstructive priority was not simply replacing the resected scapular body, but preserving the native glenohumeral joint and the small residual segment containing the glenoid, acromion, and coracoid. Preservation of these structures has been associated with superior postoperative function [3, 10, 11]. When the glenohumeral joint itself requires prosthetic reconstruction, constrained designs may provide stability but introduce risks including loosening and soft-tissue complications, without a clear functional advantage over unconstrained reconstruction [12, 13]. Double-constrained constructs may be useful when critical stabilizers must be sacrificed, but were unnecessary here because the native joint and key neuromuscular structures could be retained [14, 15].

Conclusion

This case highlights the unique reconstructive challenges posed by malignant scapular tumors in very young patients, in whom both oncologic control and long-term functional preservation are critical. The use of advanced preoperative planning, including patient-specific cutting guides and a custom 3D-printed endoprosthesis, enabled precise tumor resection with negative margins while preserving a portion of the native glenoid and the glenohumeral joint. This joint-preserving strategy proved to be a key determinant of the excellent functional outcome observed. The favorable oncologic and functional results in this case underscore the potential of patient-specific, technology-driven reconstruction to expand limb-salvage options in complex scapular tumors, particularly in the pediatric population, where durable function is of paramount importance.

Funding

None declared.

Conflicts of interest

None declared.

Institution(s) at which the work was performed: First Medical Faculty, Charles University, University Hospital Na Bulovce, Prague, Czech Republic.

References

1.

Mayil Vahanan
 
N
,
Mohanlal
 
P
,
Bose
 
JC
 et al.  
The functional and oncological results after scapulectomy for scapular tumours: 2-16-year results
.
Int Orthop
 
2007
;
31
:
831
–
6
.

2.

Lesenský
 
J
,
Mavrogenis
 
AF
,
Igoumenou
 
VG
 et al.  
Complex surgery for locally advanced bone and soft tissue sarcomas of the shoulder girdle
.
Eur J Orthop Surg Traumatol
 
2017
;
27
:
777
–
86
.

3.

Malawer
 
MM
.
Tumors of the shoulder girdle. Technique of resection and description of a surgical classification
.
Orthop Clin North Am
 
1991
;
22
:
7
–
35
.

4.

Pritsch
 
T
,
Bickels
 
J
,
Wu
 
CC
 et al.  
Is scapular endoprosthesis functionally superior to humeral suspension?
 
Clin Orthop Relat Res
 
2007
;
456
:
188
–
95
.

5.

Schwab
 
JH
,
Athanasian
 
EA
,
Morris
 
CD
 et al.  
Function correlates with deltoid preservation in patients having scapular replacement
.
Clin Orthop Relat Res
 
2006
;
452
:
225
–
30
.

6.

Fujii
 
Y
,
Nakatani
 
T
,
Ousaka
 
D
 et al.  
Development of antimicrobial surfaces using diamond-like carbon or diamond-like carbon-based coatings
.
Int J Mol Sci
 
2024
;
25
:
8593
.

7.

Zia
 
AW
,
Tuñón-Molina
 
A
,
Anestopoulos
 
I
 et al.  
Concurrent biocompatibility and antimicrobial functionality of soft diamond-like carbon coating for healthcare applications
.
Adv Healthc Mater
 
2025
;
14
:e2501224.

8.

Ipponi
 
E
,
Cordoni
 
M
,
Bechini
 
E
 et al.  
Clinical and functional results after total scapulectomy in orthopedic oncology: are custom-made scapular prostheses better than humeral suspension?
 
Proc (Bayl Univ Med Cent)
 
2024
;
37
:
553
–
9
.

9.

Deng
 
L
,
Zhao
 
X
,
Wei
 
C
 et al.  
Application of a three-dimensional printed segmental scapula prosthesis in the treatment of scapula tumors
.
J Int Med Res
 
2019
;
47
:
5873
–
82
.

10.

Yu
 
XJ
,
Liu
 
QK
,
Wang
 
YG
 et al.  
Oncologic and functional outcomes of different reconstruction modalities after resection of chondrosarcoma of the scapula: a medium- to long-term follow-up study
.
BMC Musculoskelet Disord
 
2022
;
23
:
758
.

11.

Hayashi
 
K
,
Iwata
 
S
,
Ogose
 
A
 et al.  
Factors that influence functional outcome after total or subtotal scapulectomy: Japanese musculoskeletal oncology group (JMOG) study
.
PloS One
 
2014
;
9
:e100119.

12.

Min
 
L
,
Zhou
 
Y
,
Tang
 
F
 et al.  
Reconstruction with scapular hemiarthroplasty endoprosthesis after scapulectomy for malignant tumour
.
Int Orthop
 
2017
;
41
:
1057
–
63
.

13.

Cundy
 
WJ
,
McArthur
 
MS
,
Dickinson
 
IC
 et al.  
Constrained or unconstrained shoulder replacement for musculoskeletal tumor resections?
 
J Shoulder Elbow Surg
 
2020
;
29
:
2104
–
10
.

14.

Lesensky
 
J
,
Belzarena
 
AC
,
Daniel
 
M
.
Reconstruction with a double-constrained implant design after complex shoulder extra-articular resection
.
World J Surg Oncol
 
2023
;
21
:
295
.

15.

Beltrami
 
G
,
Ristori
 
G
,
Scoccianti
 
G
 et al.  
Latissimus dorsi rotational flap combined with a custom-made scapular prosthesis after oncological surgical resection: a report of two patients
.
BMC Cancer
 
2018
;
18
:
1003
.

This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact reprints@oup.com for reprints and translation rights for reprints. All other permissions can be obtained through our RightsLink service via the Permissions link on the article page on our site—for further information please contact journals.permissions@oup.com.
Close
This Feature Is Available To Subscribers Only

Sign In or Create an Account

Close

This PDF is available to Subscribers Only

View Article Abstract & Purchase Options

For full access to this pdf, sign in to an existing account, or purchase an annual subscription.

Close

Gift article access

As a benefit of your subscription, you can share temporary access to restricted articles.

Each link will stop working after 30 days or 10 uses. You may create up to 10 links in a 30 day period.

Please sign in to your personal account to gift article access.

Gift article access

Please create a link below to share with others. This will provide temporary access to this restricted article.

The link will stop working after 30 days or 10 uses. You may create up to 10 links in a 30 day period.

Gift articles remaining: --

Gift article access

The link will stop working after 30 days or 10 uses. You may create up to 10 links in a 30 day period.

Gift articles remaining: --

Gift article access

As a benefit of your subscription, you can share temporary access to restricted articles.

Each link will stop working after 30 days or 10 uses.

You have reached the limit of 10 links within a 30 day period