PDF
- Split View
-
Views
-
Cite
Cite
Lutfi İhsan Boyaci, Necip Fazıl Aras, Circumcision under local anesthesia in a selected case with buried penis: a technique using the Alisklamp Nero M, Journal of Surgical Case Reports, Volume 2026, Issue 10, October 2026, rjag960, https://doi.org/10.1093/jscr/rjag960
Close - Share Icon Share
Abstract
Circumcision in patients with buried penis remains controversial because of the risk of recurrent concealment and secondary complications. This report describes a circumcision technique performed under local anesthesia in a selected case of buried penis. The technique preserves the outer preputial skin while excising only the inner preputial mucosa, using the Alisklamp Nero M device to achieve symmetrical mucosal alignment and protect the glans. Deep Buck's fascia-incorporating sutures at the 3- and 9-o’clock positions enhance penile stability. No early postoperative complications were observed. Because this is a single-case technical report without long-term follow-up data, the findings should be interpreted cautiously.
Introduction
Circumcision has long been practiced worldwide for medical, religious, and cultural reasons [1–3].
Circumcision can be performed under general or local anesthesia using either conventional surgical techniques or device-assisted methods. Conventional surgical techniques include the sleeve technique, dorsal slit, and forceps-guided methods, whereas device-assisted circumcision involves the use of devices such as Plastibell, Alisklamp, Mogen clamp, and Gomco clamp [1, 4]. During circumcision, tissue excision can be performed using scalpel and scissors, as well as energy-based modalities such as bipolar diathermy and thermal cautery [1, 5]. To date, no universally accepted gold standard technique for circumcision has been established.
In cases of buried penis, circumcision has traditionally been considered controversial due to the risk of complications such as insufficient residual prepuce, secondary phimosis, and recurrent penile concealment [1, 6, 7]. The aim of this study is to describe a circumcision technique using the Alisklamp Nero M device that may facilitate circumcision under local anesthesia in a selected case with buried penis.
Case presentation
Five-month-old infant with buried penis presented to our clinic at his family's request for circumcision under local anesthesia (Fig. 1).

Preoperative appearance of the patient with buried penis.
Local anesthesia was achieved with 0.5% bupivacaine at a dose of 2 mg/kg using a penile ring block.
The physiological adhesions between the glans penis and the prepuce were released, and accumulated smegma on the glans surface was removed.
The inner preputial mucosa was grasped with a hemostatic clamp at the 12 o’clock position, ~1 cm distal to the junction with the outer preputial skin (Fig. 2a), and a dorsal slit was performed on the inner preputial mucosa using a thermocautery device (Thermo-Med TM 802B device; Thermo Medikal, Adana, Turkiye).

Surgical steps of the this circumcision technique using the Alisklamp Nero M device. (a) The inner preputial mucosa is grasped and a dorsal slit is performed. (b) Placement of the inner component of the Alisklamp Nero M device. (c) Alignment of the inner preputial mucosa to achieve symmetrical mucosal length. (d) Excision of the prepuce using a thermocautery device. (e) Final appearance after completion of the procedure.
The tubular inner component of the Alisklamp Nero M(Ankara, Turkiye) device was placed over the glans penis (Fig. 2b), followed by positioning of the outer component onto the inner tube. The screw mechanism was then applied and gradually tightened; however, at this stage, it was intentionally left loose enough to allow free movement of the prepuce between the inner and outer components. Only the inner mucosal layer of the prepuce was aligned between the inner and outer components of the device. The mucocutaneous junction was positioned at the lower border of the outer component. This alignment was achieved by gently tractioning the mucosa with a mosquito clamp (Fig. 2c). Which the screw mechanism was fully tightened to secure the final position.
The prepuce was then excised using thermocautery device (Fig. 2d).
Following removal of the screw mechanism, the inner and outer components of the device were separated. After reassessment of mucosal symmetry, the suturing phase was initiated. Absorbable sutures (5/0 polyglycolic acid) were placed from skin to mucosa at the 12, 2, 3, 5, 6, 7, 9, and 11 o’clock positions. Sutures placed at the 3 and 9 o’clock positions were passed through deeper layers, including the skin, Buck’s fascia, and mucosa. The surgical procedure was then completed (Fig. 2e).
The patient was followed for 6 months after surgery. At these visits [1 week (Fig. 3a), 1 month (Fig. 3b), 3 months (Fig. 3c), and 6 months (Fig. 3d)], no recurrent concealment, infection, wound dehiscence, or unfavorable esthetic outcomes were observed.

Postoperative follow-up. (a) One week after surgery. (b) One month after surgery. (c) Three months after surgery. (d) Six months after surgery.
Discussion
In cases of buried penis, the feasibility and optimal timing of circumcision remain controversial [1, 6, 7]. Due to risks such as recurrent concealment, insufficient residual prepuce, and secondary phimosis, techniques that require more extensive surgical dissection, often performed under general anesthesia and involving the placement of fixation sutures between the penile skin and Buck’s fascia at the penopubic and penoscrotal regions, are commonly preferred in these patients [8, 9].
The technique described in this study offers an approach that allows circumcision to be performed under local anesthesia in a selected case of buried penis using the Alisklamp Nero M device. By limiting excision exclusively to the inner mucosal layer of the prepuce while fully preserving the outer preputial skin, the technique may contribute to maintaining a more natural penile appearance.
The fixed distance between the inner and outer components of the Alisklamp device allows symmetrical adjustment of the mucosal length and may reduce the need for additional corrective maneuvers. Mechanical protection of the glans by the inner tube facilitates safer surgical handling and helps preserve anatomically safe planes. In this case, the chromed structure of the device permitted the use of thermocautery device, and no intraoperative bleeding was observed.
Deep sutures placed at the 3 and 9 o’clock positions, incorporating Buck’s fascia while respecting anatomically safe zones, are thought to provide supportive fixation that may help prevent retraction of the glans into the surrounding skin.
The absence of complications during the 6-month follow-up period supports the short- to mid-term feasibility of the technique. Recurrent penile concealment over time may be influenced by factors such as the child’s growth, body weight, and the amount of adipose tissue in the pubic region. As the described technique is not primarily intended to modify these factors, a preventive effect on long-term recurrent concealment cannot be assumed.
Several limitations of this technique should be acknowledged. Its applicability depends on appropriate size compatibility between the penis and the available Alisklamp device. Safe and effective implementation requires adequate surgeon experience with the device. In cases involving other subtypes of concealed penis, such as the presence of a penoscrotal web or secondary phimosis, additional surgical interventions may be required, and the described technique may not be suitable.
This study is not intended as an alternative to formal buried penis repair. Rather, it is a technical description based on a single case, demonstrating a technique that may facilitate circumcision under local anesthesia in children with buried penis, in whom circumcision can be technically challenging.
However, given that the technique is based on a single case and that long-term outcome data are currently lacking, the findings should be interpreted with caution. Further studies involving larger patient series and longer follow-up are needed to evaluate late outcomes such as recurrent concealment, skin tethering, or persistent lymphedema and to establish the safety and effectiveness of this technique.
Conflicts of interest
The authors declare that they have no conflicts of interest.
Funding
The authors received no financial support for the research, authorship, or publication of this article.
Ethical approval statement
Written informed consent for publication was obtained from the patient's legal guardians.
Declaration of generative AI and AI-assisted technologies in the manuscript preparation process
During the preparation of this manuscript, the authors used ChatGPT (OpenAI) for English language editing and manuscript organization. The authors reviewed and approved all content and take full responsibility for the final manuscript.