Journal Article

Laparoscopic retrieval of an intra-abdominal sewing needle following unrecognized penetration: a case report

Journal of Surgical Case Reports, Volume 2026, Issue 10, October 2026, rjag1012, https://doi.org/10.1093/jscr/rjag1012
Published:
31 October 2026
Article history
Received:
28 August 2026
Accepted:
12 October 2026
Published:
31 October 2026

Abstract

Unrecognized transcutaneous penetration by a small sharp foreign body is rare and may present without a clear history of injury. A 50-year-old woman presented with abdominal pain and was found to have a 4-cm linear metallic foreign body within the peritoneal cavity. After initial observation, she represented with recurrent pain and radiographic migration of the object, later recalling that she may have rolled onto a sewing needle while asleep. At diagnostic laparoscopy the needle was not immediately visible. Sequential intraoperative radiographs, using a laparoscopic grasper as a radiopaque reference point, enabled localization of the needle within greater omentum adjacent to the transverse colon. It was removed laparoscopically without visceral injury. This case demonstrates the value of targeted intraoperative radiography when a small radiopaque foreign body cannot be identified during minimally invasive exploration.

Introduction

Sharp intra-abdominal foreign bodies may enter through ingestion, iatrogenic introduction, or penetrating trauma. Unrecognized transcutaneous entry is uncommon and may delay diagnosis. Sharp objects can migrate and injure bowel, mesentery, or vessels, making accurate localization and timely management important. We report laparoscopic retrieval of a sewing needle after unrecognized transcutaneous penetration, using intraoperative radiography when direct visualization was unsuccessful.

Case report

A 50-year-old woman was referred to the emergency department with a 1-day history of acute central and epigastric abdominal pain. She denied bowel or urinary symptoms. Examination demonstrated mild central abdominal tenderness without guarding or peritonism and sinus tachycardia of 130 beats/min. Laboratory investigations were unremarkable. Computed tomography demonstrated an approximately 4-cm linear extraluminal metallic foreign body in the left abdomen, without free gas, collection, or surrounding inflammatory change.

She was admitted overnight for observation but could not initially identify a possible mechanism of entry. Her pain resolved and repeat plain radiography showed the object in a similar position. As its relationship to her symptoms remained uncertain, she was discharged with close surgical follow-up and return precautions.

The following day she represented with recurrent abdominal pain and left lower quadrant tenderness. Repeat radiography demonstrated interval inferior migration of the foreign body without free subdiaphragmatic gas. She then recalled falling asleep while sewing and believed she may have rolled onto a sewing needle. Given recurrent symptoms, demonstrated migration, and the risk of visceral or vascular injury, operative retrieval was undertaken.

Diagnostic laparoscopy identified a small haematoma at the root of the small-bowel mesentery, without active bleeding or enteric contamination. The small bowel, colon, and visualized solid organs were otherwise intact. The needle was not visible despite careful inspection. Sequential intraoperative radiographs were therefore obtained from different projections. A fenestrated laparoscopic grasper was used as a radiopaque reference point, allowing triangulation of the needle (Fig. 1).

For image description, please refer to the figure legend and surrounding text.
Figure 1

Image of localization of needle intra-operatively using X-ray and a fenestrated grasper.

The needle was encapsulated within the greater omentum adjacent to the transverse colon. A small opening was created with diathermy and the needle was removed atraumatically through a 5-mm port (Supplementary Video S1). Systematic inspection showed no bowel perforation, serosal injury, or ongoing haemorrhage, and the procedure was completed laparoscopically. The patient was discharged on postoperative day 1. She subsequently represented with mild periumbilical cellulitis without a collection, which resolved with oral antibiotics; no further complication was documented.

Discussion

Intra-abdominal foreign bodies arise through accidental penetration, ingestion, iatrogenic introduction and, less commonly, deliberate self-harm, or interpersonal violence. Deliberate transabdominal insertion has been described in psychiatric and custodial populations, but the rarity of this mechanism means reliable population incidence estimates are not available [1]. Sharp retained objects are clinically important because migration can cause perforation, abscess, fistula, and vascular or mesenteric injury [2, 3]. The greater omentum may encapsulate foreign material and limit further migration, as occurred in this case (Fig. 2) [4].

For image description, please refer to the figure legend and surrounding text.
Figure 2

Image of retrieved needle in a specimen jar.

Management should be individualized according to the object’s composition, shape, location, mobility, and associated injury. A mobile sharp intraperitoneal object generally favours removal because of the risk of subsequent visceral injury. Not all retained metallic fragments require extraction: ballistic literature supports selective retention of asymptomatic fragments when removal would cause greater morbidity, with removal reserved for particular locations or complications [5]. Computed tomography provides the best anatomical definition of a radiopaque foreign body and associated injury, while serial plain radiographs can demonstrate interval migration but provide limited depth information [3, 6].

For haemodynamically stable patients without generalized peritonitis, laparoscopy provides both diagnosis and treatment while allowing systematic inspection of the abdominal cavity. Compared with laparotomy in selected abdominal trauma patients, meta-analysis has associated laparoscopy with fewer wound infections and a shorter hospital stay, by approximately 3.8 days, although study heterogeneity is substantial [7]. Laparotomy remains appropriate for haemodynamic instability, generalized peritonitis, suspected major vascular injury, or when exposure, anatomy or operative progress is inadequate for safe minimally invasive management.

The principal laparoscopic pitfall is missed injury, particularly hollow-viscus or mesenteric injury. An older prospective study identified only 57% of significant injuries at diagnostic laparoscopy and reported sensitivity below 50% for hollow-viscus injury [8]; contemporary pooled data suggest a much lower overall missed-injury rate of approximately 0.5% in appropriately selected trauma patients [7]. Surgeons should therefore perform a deliberate bowel and mesenteric survey, be prepared to repair bowel or vascular injury laparoscopically, and convert promptly when safe assessment or treatment cannot be achieved. In the present case, targeted intraoperative radiography with a laparoscopic instrument as a radiopaque reference enabled accurate localization when direct inspection failed, supporting its use as an accessible adjunct for small metallic foreign bodies [6, 9, 10].

Conflicts of interest

None declared.

Funding

No funding was received for this work.

Patient consent

Written patient consent was obtained for publication prior to submission.

References

1.

Paulino
 
AF
,
Krolikowski
 
FJ
.
Insertion of foreign bodies into the abdominal cavity: an unusual form of self-mutilation
.
Am J Forensic Med Pathol
 
1995
;
16
:
48
–
50
.

2.

Goh
 
BK
,
Tan
 
YM
,
Lin
 
SE
 et al.  
CT manifestations of complications arising from ingested foreign bodies
.
AJR Am J Roentgenol
 
2006
;
187
:
710
–
4
.

3.

Gayer
 
G
,
Petrovitch
 
I
,
Jeffrey
 
RB
 Jr
.
CT diagnosis and localisation of ingested and penetrating foreign bodies
.
Radiographics
 
2011
;
31
:
123
–
38
.

4.

Gümüş
 
M
,
Gürkan
 
A
,
Özdemir
 
H
 et al.  
Encapsulated intra-abdominal needle mimicking chronic abdominal pain
.
World J Clin Cases
 
2015
;
3
:
875
–
8
.

5.

Riehl
 
JT
,
Sassoon
 
A
,
Connolly
 
K
 et al.  
Retained bullet removal in civilian pelvis and extremity gunshot injuries: a systematic review
.
Clin Orthop Relat Res
 
2013
;
471
:
3956
–
60
.

6.

Lee
 
JY
,
Yoon
 
HS
,
Yoon
 
CS
 et al.  
Radiologic localisation of small metallic foreign bodies
.
Korean J Radiol
 
2001
;
2
:
17
–
23
.

7.

Wang
 
J
,
Cheng
 
L
,
Liu
 
J
 et al.  
Laparoscopy vs. laparotomy for the management of abdominal trauma: a systematic review and meta-analysis
.
Front Surg
 
2022
;
9
:817134.

8.

Elliott
 
DC
,
Rodriguez
 
A
,
Moncure
 
M
 et al.  
The accuracy of diagnostic laparoscopy in trauma patients: a prospective, controlled study
.
Int Surg
 
1998
;
83
:
294
–
8
.

9.

Barakzai
 
M
,
Haq
 
T
,
Khandwala
 
K
.
Non-surgical retrieval of dislodged or misplaced intravascular/endoluminal foreign objects
.
Cureus
 
2019
;
11
:e3931.

10.

Afzali
 
M
,
Shojaie
 
P
,
Iyengar
 
K
 et al.  
Intraoperative radiological imaging: an update on modalities in trauma and orthopedic surgery
.
JAJS
 
2023
;
10
:
54
–
61
.

This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
Close
This Feature Is Available To Subscribers Only

Sign In or Create an Account

Close

This PDF is available to Subscribers Only

View Article Abstract & Purchase Options

For full access to this pdf, sign in to an existing account, or purchase an annual subscription.

Close

Gift article access

As a benefit of your subscription, you can share temporary access to restricted articles.

Each link will stop working after 30 days or 10 uses. You may create up to 10 links in a 30 day period.

Please sign in to your personal account to gift article access.

Gift article access

Please create a link below to share with others. This will provide temporary access to this restricted article.

The link will stop working after 30 days or 10 uses. You may create up to 10 links in a 30 day period.

Gift articles remaining: --

Gift article access

The link will stop working after 30 days or 10 uses. You may create up to 10 links in a 30 day period.

Gift articles remaining: --

Gift article access

As a benefit of your subscription, you can share temporary access to restricted articles.

Each link will stop working after 30 days or 10 uses.

You have reached the limit of 10 links within a 30 day period